Sutherland Shire DCP and LEP controls for house DAs

Sutherland Shire LEP 2015 and Sutherland Shire DCP 2015 apply to houses on land covered by the LEP. The controls below cover R2 houses under DCP Chapter 2c; height, floor space ratio and landscaped area are mapped LEP standards.

Checked against the plans in force on 5 October 2026.

Which plans apply

Key controls for a house

R2 Low Density Residential: Sutherland Shire DCP 2015 Chapter 2c

Building height8.5m is a common R2 maximum; the Height of Buildings Map sets the limit for your lot.Sutherland Shire LEP 2015 cl 4.3(2); Height of Buildings Map
Landscaped area35% is a common R2 minimum; check the Landscape Area Map for your lot, separately from the DCP front garden requirement.Sutherland Shire LEP 2015 cl 6.14(2), (3); Landscape Area Map
Floor space ratio0.55:1 is a common R2 maximum; check the Floor Space Ratio Map for your lot and calculate gross floor area using the LEP Dictionary.Sutherland Shire LEP 2015 cl 4.4(2), 4.5; Dictionary; Floor Space Ratio Map
Side setback0.9m minimum at ground floor; 1.5m for the second storey, internal lots and bush fire prone land, with increases for long walls, overshadowing or visual intrusion explained below.Sutherland Shire DCP 2015 Ch 2c 2.2(2), (6)
Front setback7.5m minimum to the primary, narrowest street frontage, or the established street setback where adjoining houses sit further forward or back; 3m to a secondary street; 4m for an internal lot.Sutherland Shire DCP 2015 Ch 2c 2.2(2), (5)
Rear setback6m minimum, or 4m for an internal lot.Sutherland Shire DCP 2015 Ch 2c 2.2(2)
Front garden50% maximum hard surfaces in the front setback; the remaining 50% must be deep soil landscaping.Sutherland Shire DCP 2015 Ch 2c 4.2(1)
Private open space36m² minimum per dwelling, with a minimum dimension of 5m and 9m² of paving; front setback locations need the privacy treatment explained below.Sutherland Shire DCP 2015 Ch 2c 5.2(3), (4)
Car parking2 spaces per house, with at most 2 above ground and only 2 visible from the street; basement parking has no stated maximum if all basement objectives and controls are met.Sutherland Shire DCP 2015 Ch 36 1.2, Table 1

Issues to resolve before you lodge

  1. 1

    Retaining canopy trees

    In R2, development should retain existing canopy trees near side, rear and front setbacks, including on adjoining land (DCP Ch 2c 4.2(2)).

  2. 2

    Sunlight to private open space

    In R2, 10m² of the proposed dwelling’s private open space must have 3 hours of solar access between 9am and 3pm on 21 June (DCP Ch 2c 5.2(5)(b)).

  3. 3

    Front setback privacy

    In R2, private open space in the front setback must use fencing and hedging for privacy while contributing to the street’s landscaped character, and high solid fencing is unacceptable (DCP Ch 2c 5.2(4)).

Documents you may need

  • A written variation request where relying on LEP cl 4.6, identifying each standard and addressing why compliance is unreasonable or unnecessary and the sufficient environmental planning grounds for the departure.
  • An arboricultural impact assessment for works within 5m of a tree, irrespective of boundaries, except on-site trees on the DCP exempt-species list: Council’s Lodgement requirements and DCP Ch 39 4.16.
  • A geotechnical report for bulk basement excavation more than 1m below natural ground, any bulk excavation on steep or sloping sites, or works close to a cliff: Council’s Lodgement requirements.
  • Additional hourly or elevational shadow diagrams where the proposal is likely to overshadow adjoining windows, showing existing and proposed effects on living areas and private open space: Council’s Lodgement requirements and DCP Ch 2c 5.2.

Check your plans against Sutherland Shire’s rules

$249. Key figures recomputed from your plans and the issues council is likely to raise, each with a fix, in under 24 hours.

Check a DA

Questions

Which Sutherland Shire DCP chapter applies to my house?

DCP Chapter 2 has a section for each of the C3, C4, R2, R3, R4, E1 and SP3 zones (this table uses Chapter 2c for R2); in another zone, check the LEP and the DCP’s general and site-specific chapters. Land marked Deferred matter needs a separate check of the saved planning instruments.

What is the side setback for a house in Sutherland Shire?

In R2, the minimum is 0.9m at ground floor and 1.5m for the second storey, with 1.5m required on internal lots and bush fire prone land. A second-storey side wall longer than 15m continuously needs at least another 500mm for that part, and significant overshadowing or visual intrusion can require more: DCP Ch 2c 2.2.

How much landscaped area does an R2 house need?

35% is a common R2 minimum, but the Landscape Area Map sets your lot’s requirement under LEP cl 6.14, excluding buildings, structures and hard paved areas from landscaping. Separately, DCP Ch 2c 4.2 requires 50% of the front setback to be deep soil landscaping.

General information, not planning advice. Plans change and some controls are mapped lot by lot: check the current LEP and DCP, and the planning certificate for your lot, before relying on a figure.