Inner West DCP and LEP controls for house DAs

Start with the LEP land application map and the DCP boundary for the former Ashfield, Leichhardt or Marrickville area. Check the lot’s mapped controls, neighbourhood and heritage requirements before using the house rules below.

Checked against the plans in force on 5 October 2026.

Which plans apply

Key controls for a house

Statutory controls: Inner West LEP 2022

Building heightSet by the Height of Buildings Map: check the map for your lot, including any mapped area conditions in clause 4.3.Inner West LEP 2022 clause 4.3

Former Ashfield area: R2 houses outside heritage items and conservation areas

Side and front setbacks900mm minimum side setback along the entire building; front setbacks follow the predominant adjoining and nearby building line, with minor variations considered where sympathetic to the streetscape or enhancing the architecture.Ashfield DCP 2016 Chapter F Part 1, DS4.1, DS4.3–DS4.4
Wall height and storeys6m maximum external wall height from existing ground level, with a 2-storey appearance; minor variations require the DS3.5 conditions, and the LEP building-height limit also applies.Ashfield DCP 2016 Chapter F Part 1, DS3.3–DS3.5
Principal private open space20m² minimum, with a 3.5m minimum dimension, directly accessible from and level with ground-floor living space; provide appropriate sunlight, natural ventilation and privacy.Ashfield DCP 2016 Chapter F Part 1, DS9.1
Minimum landscaped area25% on 201–300m² lots; 28% on 301–400m²; 32% on 401–500m²; 35% on 501–600m² and ≥601m², with variations considered where necessary for heritage conservation.Ashfield DCP 2016 Chapter F Part 1, DS8.2, DS8.4
Maximum site coverage65% on 201–300m² lots; 60% on 301–400m²; 55% on 401–500m²; 50% on 501–600m² and ≥601m².Ashfield DCP 2016 Chapter F Part 1, DS8.3
Lots of 0–200m²20m² courtyard with 3.5m minimum width, plus front garden and principal private open-space requirements: landscaping is assessed on merit; coverage is assessed on merit subject to minimum landscaping.Ashfield DCP 2016 Chapter F Part 1, DS8.2–DS8.3

Former Leichhardt area: Leichhardt DCP 2013

Side, front and rear setbacksUse Figure C129 for each wall’s height and side setback; front and rear setbacks follow the Building Location Zone from adjoining main buildings, floor by floor, with specific corner and uncharacteristic-setback provisions.Leichhardt DCP 2013 C3.2 C3–C8
Building envelope2.4m, 3.6m, 6m and 7.2m are basic envelopes with 45° roof planes; use the neighbourhood’s specific wall-height control for street and public-land frontages, alongside separate laneway envelopes.Leichhardt DCP 2013 C2; C3.2 C13–C16, C20
Private open space16m² minimum recommended, with a 3m minimum dimension, directly connected to principal indoor living areas; exclude the front setback and apply the ground-level and constrained-site provisions in C3.8 C1.Leichhardt DCP 2013 C3.8 C1

Former Marrickville area: Marrickville DCP 2011, R2 houses

Side setbacks900mm for 1 storey, 1.5m for 2 storeys, 2.5m for 3 storeys on lots ≥8m wide; below 8m, council considers visual impact, adjoining solar access and street context.Marrickville DCP 2011, 4.1.6.2 C10(ii), C12
Front and rear setbacksMatch adjoining or dominant front setbacks and consistent secondary setbacks on opposite corners; aim to retain a predominant, consistent first-floor rear line visible from the public domain, otherwise assess rear amenity and open space.Marrickville DCP 2011, 4.1.6.2 C10, C12
Site coverage60% maximum on >300–350m² lots; 55% on >350–400m²; 50% on >400–500m²; 45% on >500–700m²; 40% on >700m²; 0–300m² lots are assessed on merit using site and context analysis.Marrickville DCP 2011, 4.1.6.3 C13
Private open space45m² or 20% of total site area, whichever is greater, with no dimension below 3m; exclude the front setback.Marrickville DCP 2011, 2.18.11.1 C12
Pervious landscaping50% minimum of private open space must be pervious; the entire front setback must be pervious landscaping except driveways and pathways.Marrickville DCP 2011, 2.18.11.1 C11–C12

Issues to resolve before you lodge

  1. 1

    Floor space ratio

    House floor space ratio is limited by the lot’s mapped controls and applicable area-specific tables (Inner West LEP 2022 clause 4.4(2), (2B)–(2C)).

  2. 2

    Sunlight to neighbouring windows

    For Ashfield houses outside heritage sites, at least 40% of neighbouring north-facing primary living-area glazing must retain at least 3 hours of sunlight between 9am and 3pm on 21 June, or existing sunlight if already below this (Ashfield DCP Chapter F Part 1 DS13.2).

  3. 3

    Privacy between neighbouring homes

    In Leichhardt, sightlines within 9m and 45 degrees between adjoining dwellings’ living rooms or private open space must be screened or obscured unless direct views are restricted or separated by a street or laneway (Leichhardt DCP C3.11 C1).

Documents you may need

  • Heritage impact statement for Marrickville development on land containing a heritage item, in a conservation area or in their vicinity, assessing significance, proposed changes, impacts and mitigation in detail proportionate to the work (8.1.8–8.1.8.1).
  • Arborist report where Leichhardt development enters the protection zone of a tree on an adjoining site (C1.12).
  • Shadow diagrams and solar-access analysis for Leichhardt external additions or new building work (C3.9 C1).
  • Landscape concept plan for Ashfield house applications covered by Chapter F Part 1 DS8.1.

Check your plans against Inner West’s rules

$249. Key figures recomputed from your plans and the issues council is likely to raise, each with a fix, in under 24 hours.

Check a DA

Questions

Which Inner West DCP applies to my house?

Check the DCP boundary for the former Ashfield, Leichhardt or Marrickville area, then the applicable heritage and neighbourhood or precinct controls. Ashfield Chapter F Part 1 applies to heritage sites only where expressly stated, and Leichhardt DCP 2013 excludes its identified deferred land.

What is the Inner West DCP side setback?

Ashfield’s general house rule is 900mm outside heritage sites; Marrickville requires 900mm for 1 storey, 1.5m for 2 storeys and 2.5m for 3 storeys on lots at least 8m wide, with narrower lots assessed on merit. Leichhardt uses the wall-height graph in C3.2 Figure C129.

General information, not planning advice. Plans change and some controls are mapped lot by lot: check the current LEP and DCP, and the planning certificate for your lot, before relying on a figure.