Cumberland DCP and LEP controls for house DAs

Cumberland LEP 2021 and Cumberland DCP 2021 apply to house DAs on residential land covered by the LEP, with Part B1 covering houses and secondary dwellings. Check precinct controls and applicable State planning policies first: precinct controls prevail over the general DCP where they conflict, and State policies can override local controls.

Checked against the plans in force on 5 October 2026.

Which plans apply

Key controls for a house

General house controls, including R2: check precinct rules and State policies

Front setback6m minimum to the primary frontage, aligned with the street; balconies, porticos and entrances may project up to 0.9m into this setback, within the maximum 0.9m articulation zone.Cumberland DCP 2021 Part B1 2.1 Table 1 and 2.4
Side and rear setbacks0.9m minimum side setback; 8m minimum rear setback.Cumberland DCP 2021 Part B1 2.1 Table 1
Height and storeys9m maximum on most R2 land: check the Height of Buildings Map for your lot. Houses, including alterations and additions: maximum 2 storeys and minimum 2.7m floor to ceiling.Cumberland LEP 2021 cl 4.3, Height of Buildings Map; Cumberland DCP 2021 Part B1 2.2
Floor space ratioMost R2 land has no mapped floor space ratio: check the Floor Space Ratio Map for your lot. DCP site coverage, landscaping and storey controls still apply.Cumberland LEP 2021 cl 4.4, Floor Space Ratio Map; Cumberland DCP 2021 Part B1 2.2, 2.6 and 2.7
Site coverage70% maximum on lots 450m² or less; 65% on lots 451m² or greater, including outbuildings and any secondary dwelling together with the principal house.Cumberland DCP 2021 Part B1 2.6 Table 2, 2.20 and 2.21
Landscaped area and deep soil15% minimum on lots 450m² or less; 20% on lots 451m² or greater, all as deep soil at least 1m wide; the rear layout requirements below also apply.Cumberland DCP 2021 Part B1 2.7 Table 3 and controls
Private open space50m² minimum on lots over 451m²; 30m² on lots 450m² or smaller, at ground level beside or behind the house with direct living area access; see minimum dimensions below.Cumberland DCP 2021 Part B1 2.8
Parking and garages1 covered space minimum, 2 covered spaces maximum per house; at-grade garages and carports at least 1m behind the front wall, subject to the detached-carport exceptions in Part G3 4.2.Cumberland DCP 2021 Part G3 3 Table 1 and 4.2

Issues to resolve before you lodge

  1. 1

    Deep soil at the rear

    The majority of the deep soil zone must form a consolidated area at the rear of the house extending across at least 50% of the rear boundary (DCP Part B1 2.7).

  2. 2

    Private open space dimensions

    Private open space must have a minimum dimension of 4m in any direction, with a 3m minimum dimension considered on lots 450m² or smaller (DCP Part B1 2.8).

  3. 3

    Sunlight to homes and gardens

    Subject and adjoining properties must receive at least 3 hours of sunlight to one or more living areas and at least 50% of private open space between 8am and 4pm on 21 June; existing shortfalls should not be unreasonably reduced (DCP Part B1 2.11).

Documents you may need

  • Stormwater concept plan at lodgement for minor residential development, or detailed plans by a qualified stormwater engineer or equivalent for major development, under Part G4 2.3.
  • Arborist report and/or tree protection plan if council requires them for retained trees under Part G7 2.2, including protection of neighbouring trees affected by the works.
  • Landscape plan where required under Part G7 2.3, prepared by an appropriately qualified person with a plant schedule and enough detail for construction.
  • Heritage impact statement where required under LEP cl 5.10 and DCP Part G2, subject to council’s minor-impact waiver in Part G2 2.1 and the specific conservation-area requirements in 2.3.

Check your plans against Cumberland’s rules

$249. Key figures recomputed from your plans and the issues council is likely to raise, each with a fix, in under 24 hours.

Check a DA

Questions

Which DCP applies to a house in Cumberland?

Cumberland DCP 2021 applies where council is the consent authority, with Part B1 for houses and secondary dwellings in residential zones, Part G for general controls and Part F prevailing where precinct controls conflict. Under Part A 1.1.4, applications lodged before the DCP commenced and still undetermined at commencement use the earlier applicable controls.

What is the Cumberland DCP side setback?

For a dwelling house under Part B1 2.1 Table 1, the minimum side setback is 0.9m and the minimum rear setback is 8m. Check precinct controls and whether the proposal is a house or a secondary dwelling before applying these figures.

How much landscaped area does a Cumberland house need?

Part B1 2.7 requires at least 15% on lots 450m² or less and 20% on lots 451m² or greater; confirm the requirement with council for a lot between those bands. This must be deep soil at least 1m wide, mostly consolidated at the rear across at least 50% of the rear boundary, excluding planting on slabs or above structures.

General information, not planning advice. Plans change and some controls are mapped lot by lot: check the current LEP and DCP, and the planning certificate for your lot, before relying on a figure.