Ku-ring-gai DCP and LEP controls for house DAs

Ku-ring-gai LEP 2015 sets the statutory controls, with DCP Part 4 covering detached houses and ancillary development.

Checked against the plans in force on 5 October 2026.

Which plans apply

Key controls for a house

R2 Low Density Residential: house controls

LEP building heightSet by the Height of Buildings Map: check the map for your lot.Ku-ring-gai LEP 2015, 4.3(2)
Floor space ratio: sites up to 1000m²0.4:1 maximum at 800m² or less; ((120 + 0.25 × A) / A):1 above 800m² and up to 1000m², where A is site area in m².Ku-ring-gai LEP 2015, 4.4(2A), 4.5
Floor space ratio: sites above 1000m²((170 + 0.2 × A) / A):1 maximum above 1000m² and up to 1700m²; 0.3:1 above 1700m², where A is site area in m².Ku-ring-gai LEP 2015, 4.4(2A), 4.5
Built-upon area across the site60%/58% below 800m²; 58%/56% at 800–899m²; 56%/54% at 900–999m²; 54%/52% at 1000–1199m²; 52%/50% at 1200–1500m²; 50%/50% above 1500m²: maximum single storey/two storey BUA, subject to the alterations concession below.Ku-ring-gai DCP Part 4, 4A.3(1)
Side setbacks: sites below 20m wide1.5m minimum for single storey buildings and single storey elements of two storey buildings; 2m for two storey buildings, including upper levels, on sites less than 20m wide.Ku-ring-gai DCP Part 4, 4A.2(8)
Side setbacks: sites at least 20m wide9% of site width minimum for single storey buildings and single storey elements of two storey buildings; 12% for two storey buildings, including upper levels, on sites at least 20m wide.Ku-ring-gai DCP Part 4, 4A.2(8)
Front setback: single storey9m minimum on the low side of the street; 12m on the high side, for single storey houses.Ku-ring-gai DCP Part 4, 4A.2(3); Part 1, 1B.1
Front setback: two storey9m minimum/11m average on the low side; 12m/14m on the high side, for two storey houses; at least 75% of the front elevation meets the average, with no more than 25% at the minimum.Ku-ring-gai DCP Part 4, 4A.2(3), (5)
Rear setback12m minimum for sites deeper than 48m; 25% of average site depth for sites less than 48m deep; confirm the requirement with council for exactly 48m.Ku-ring-gai DCP Part 4, 4A.2(6)–(7)
Parking and garage dimensions2 on-site spaces for a single occupancy dwelling, subject to 4B.3(5) siting provisions; minimum unobstructed internal garage width × length: 3m × 5.4m single, 5.4m × 5.4m double.Ku-ring-gai DCP Part 4, 4B.2(2), (5), Figure 4B.2-1

Issues to resolve before you lodge

  1. 1

    Built-upon area

    Built-upon area must meet the site-size and storey limits, except that alterations and additions on sites already over the limit are capped at the existing built-upon area (DCP 4A.3(1)).

  2. 2

    Sunlight to neighbours

    Adjoining properties must retain at least 4 hours of sun between 9am and 3pm on 21 June to north facing windows, all living areas and principal private open space, unless existing building shadows prevent this, when sunlight should not fall by more than 20% (DCP 4C.5(2), (4)).

  3. 3

    Tree protection

    Structures and services must be outside retained trees’ Tree Protection Zones, including street and adjoining trees, and existing ground levels must be maintained within those zones (DCP 21.2(5)–(6)).

Documents you may need

  • For an existing interallotment drainage easement, provide titles for the subject and affected properties and either evidence from a registered surveyor or qualified engineer of suitable infrastructure, including capacity and condition, or a scale plan for new infrastructure: DCP 24B.5(1)–(2).
  • Provide an arborist’s assessment where excavation or fill modifies levels within retained trees’ canopy spread: DCP 21.1(8), 21.2(5)–(6).
  • Geotechnical or hydrogeological reports may be needed to show earthworks will not harm retained or adjoining structures and trees, and slopes exceeding 15% may require geotechnical stability certification: DCP 21.1(2), (8).
  • Provide professionally prepared shadow diagrams for all new dwellings and alterations or additions exceeding one storey: DCP 4C.5(6).

Check your plans against Ku-ring-gai’s rules

$249. Key figures recomputed from your plans and the issues council is likely to raise, each with a fix, in under 24 hours.

Check a DA

Questions

What is the Ku-ring-gai DCP side setback?

Below 20m site width, allow 1.5m for single storey buildings or elements and 2m for two storey buildings, including upper levels; at 20m or more, allow 9% and 12% of site width respectively under 4A.2(8). Rectangular battle-axe lots have separate rules in 4A.2(16), and the building height plane also applies.

How much landscaped area does a Ku-ring-gai house need?

For an R2 house, use the lot-size and storey-based BUA table in DCP 4A.3, the separate 30% front-setback BUA cap, and the planting and tree requirements. Landscaped area and deep soil have separate definitions in 1B.1, so land outside the house footprint is not automatically landscaping.

What is the height limit for a house in Ku-ring-gai?

The LEP limit is set by the Height of Buildings Map: check the map for your lot. DCP 4C.1 specifies 9.5m including garages and basements, a two storey presentation and a separate side-boundary building height plane, subject to the LEP prevailing over inconsistent DCP controls.

General information, not planning advice. Plans change and some controls are mapped lot by lot: check the current LEP and DCP, and the planning certificate for your lot, before relying on a figure.

Other councils