Liverpool DCP and LEP controls for house DAs
Check which parts of Liverpool LEP 2008, Liverpool DCP 2008 or a precinct plan apply to your lot. The general house controls below depend on the locality, lot size and lot shape.
Checked against the plans in force on 5 October 2026.
Which plans apply
- Liverpool Local Environmental Plan 2008Land on the LEP’s Land Application Map, subject to precinct overrides, with zoning, height and floor space ratio maps to check for your lot.
- Liverpool Development Control Plan 2008Read Part 1 with the relevant house and locality parts, or check Part 8 separately for eligible Fast Track applications.
- SEPP (Precincts – Western Parkland City) 2021Separate statutory controls for mapped growth centre precincts, Edmondson Park South and the Aerotropolis, with some airport safeguards extending to surrounding land.
- Liverpool Growth Centre Precincts DCPRead the main body with the relevant schedules for covered land in Austral, Leppington North and East Leppington, including Leppington Major Centre and affected Denham Court land.
- Edmondson Park South Development Control Plan 2012Land within the plan’s mapped Edmondson Park South boundary, read with the Liverpool DCP provisions retained by section 1.4 and distinct from the Edmondson Park locality controls in Part 2.11.
- Western Sydney Aerotropolis DCP, Phase 2The initial Aerotropolis precincts, where you must check the precinct framework and whether a house is permissible before using residential controls.
Key controls for a house
General R2 house lots greater than 400m²: Liverpool DCP Part 3.2. Excludes battle-axe lots and land where locality or precinct controls replace Part 3.2.
| Control | Rule | Source |
|---|---|---|
| Height | Set by the Height of Buildings Map: check the map for your lot. | Liverpool LEP 2008 clause 4.3(2) |
| Floor space ratio | Set by the Floor Space Ratio Map: check the map and applicable LEP clauses for your lot, including the secondary dwelling in the overall site calculation. | Liverpool LEP 2008 clause 4.4; Liverpool DCP 2008 Part 3.2 section 10, note |
| Front and secondary street setbacks | 4.5m ground floor and 5.5m first floor to the front, plus 2.5m to the secondary street, on other streets. Classified roads: 7.0m front and secondary setbacks. | Liverpool DCP 2008 Part 3.2 section 3, Table 1 and Front and Secondary Setbacks control 1 |
| Side setback | 0.9m for a single storey house; 1.2m for the second storey component. Living-room doors, including family, dining and rumpus-room doors, need 4.0m to the side boundary. | Liverpool DCP 2008 Part 3.2 section 3, Table 2 and note |
| Rear setback | 4.0m for a single storey house; 7.0m for the second storey component. Living-room doors need 4.0m. Check section 8 for affected Pleasure Point lots. | Liverpool DCP 2008 Part 3.2 section 3, Table 2; section 8, Bushfire Controls for Pleasure Point |
| Landscaped area | 25% of the site and 50% of the front setback area minimum. Lawn, trees, garden beds and mulched areas can count. | Liverpool DCP 2008 Part 3.2 section 4, Landscaped Area controls 1 and 3 |
| Deep soil for trees | 4 x 6m minimum in the rear setback and 3 x 5m minimum in the front setback, both unencumbered to accommodate deep-rooted trees. | Liverpool DCP 2008 Part 3.2 section 4, Landscaped Area controls 2 and 4 |
| Private open space | 70m² minimum for Table 3’s 400–599m² lot band; 80m² for lots of 600m² or more. Include a principal area of at least 4 x 6m, directly accessible from the main living area. | Liverpool DCP 2008 Part 3.2 section 4, Private Open Space controls 1 and 5, Table 3 |
| Car parking | 2 spaces per dwelling, at least 1 behind the front setback. Each space: minimum 2.5 x 5.5m; a single garage: minimum 3m wide internally and unobstructed. | Liverpool DCP 2008 Part 3.2 section 7, controls 1–4 |
Issues to resolve before you lodge
- 1
Sunlight to neighbours
Adjoining properties must receive at least 3 hours of sunlight between 9am and 5pm on 21 June to at least one living room, rumpus room or similar and 50% of private open space (DCP Part 3.2 section 8, Overshadowing control 1).
- 2
Privacy to neighbours
First-floor habitable-room windows facing a side boundary must have a minimum sill height of 1.5m, except where they face a street or public open space (DCP Part 3.2 section 8, Privacy control 2).
- 3
Cut and fill
Cut must not exceed 600mm and fill within the slab must not exceed 1m, with all fill contained within the dwelling footprint (DCP Part 3.2 section 5, Cut and Fill of Land controls 1 and 3).
Documents you may need
- Landscape documentation with all development applications, covering planting, mature tree sizes, materials, levels, set-out and public-domain details, coordinated with engineering and service plans under Part 1 section 3.1.
- An arboricultural impact assessment before design where DCP-covered trees are on the site, adjoining land or public land, accompanied by a tree retention management plan under Part 1 sections 3.1 and 3.3.
- A stormwater drainage concept plan where the site drains to Council’s system and new drainage is required, showing a feasible outlet and any detention, with adjoining owners’ written consent at lodgement for required drainage easements (Part 1 section 6.1).
- An engineer’s flood assessment where required by the applicable floodplain controls, after identifying the flood risk, floodplain and development category under Part 1 sections 9.1–9.6.
Check your plans against Liverpool’s rules
$249. Key figures recomputed from your plans and the issues council is likely to raise, each with a fix, in under 24 hours.
Questions
Which Liverpool DCP part applies to my house?
For general R2 house lots, read Part 1 with Part 3.2 above 400m², Part 3.5 below 400m² or Part 3.3 for battle-axe lots, subject to locality exclusions. Confirm the pathway with Council for exactly 400m²; check Part 8 separately for Fast Track eligibility and full compliance.
Which areas have separate house controls?
Part 3.2 excludes Georges Fair, Middleton Grange, Greenway Views, Voyager Point and Edmondson Park where their locality parts govern. Growth centre precincts and Edmondson Park South use their precinct DCPs with any retained Liverpool DCP provisions; check the mapped boundary for your lot.
What is the Liverpool DCP side setback?
Part 3.2 section 3, Table 2 gives 0.9m for a single storey house, 1.2m for the second storey component and 4.0m for living-room doors. Part 3.5 gives 0.9m for both storeys on smaller lots, retaining 4.0m for living-room doors; check its separate zero-lot conditions and any locality or precinct controls.
General information, not planning advice. Plans change and some controls are mapped lot by lot: check the current LEP and DCP, and the planning certificate for your lot, before relying on a figure.